Errors of air conditioners General Climate: decoding of codes and ways to deal with malfunctions
Brand air conditioners General Climate, or GC, do not cause problems for their owners for a sufficiently long period after purchase. But still, like any equipment, they are subject to wear and tear and malfunction. Depending on the model, air conditioning errors General Climate are displayed on the remote control screen or displayed through various combinations of light indicators on the built-in display of the indoor unit.
After reading our article, the owners of the climate technology of this brand will know what the appearance of various symbols on the display means, and will also learn to understand the numerous combinations of indicator signals on the indoor unit of the product.
The information collected and presented by us will help the owners of the equipment to understand the methods of eliminating errors and teach them to do the right thing in case of a violation in the work.
The content of the article:
Self-diagnosis system of modern air conditioners
A new generation of household appliances is usually equipped with a self-diagnosis system designed to detect malfunctions and errors in operation when they first appear. Self-diagnosis system - a single network of sensors that monitor the status of a particular working unit of the unit.
When the air conditioner is turned on, the sensors automatically start working and continue to perform their functions in continuous mode until the device is disconnected from the power supply. Sometimes, to eliminate failures and errors, it is enough for the owner of the air conditioner to carry out simple actions with his own hand, sometimes you have to invite masters from an authorized service General Climate.
Consider possible errors and their codes in various models of air conditioners and splitGC systems, causes of their occurrence and methods of elimination. We will try to figure out in which cases handwritten actions are appropriate, and in which an experienced master should be invited.
When changing the operating parameters of the node on which the sensor is installed, an error signal is immediately sent to the control module, which is displayed on the display of the device. If necessary, the control module also locks the equipment to avoid incorrect operation of the air conditioner and its final breakdown.
Fault codes for various models air conditioners General Climate may differ from each other. We will try to consider in detail the codes of each model.
STANDART Series Error Codes
In different models of STANDART split systems, the error symbols may differ, therefore, before fixing the problem, it is necessary to clarify in the instructions the exact name of the model of the split system and its internal and external units. Only then can you start decrypting the error code.
We also define the notation:
- start indicator - Operation;
- timer - Timer;
- defrost indicator - Defrost;
- automatic mode - Auto.
When decrypting the error code, it is very important not to confuse the flashing, blinking and extinct indicators, the accuracy of determining the problem depends on this.
Common violations for STANDART 07-18 R22, R410A
In the models of the STANDART 07-18 R22, R410A split systems, error signals are generated using various combinations of light indicators.
Operation flashes quickly, Timer is off - fan stops for more than 1 minute.
Operation flashes quickly, Timer is on - a broken pipe temperature sensor.
Operation is not turned on, Timer flashes quickly - high voltage is supplied to the compressor 4 times.
Operation is on, Timer is flashing quickly - EEPROM error.
Operation flashes quickly, Timer flashes quickly - the compressor does not turn on or there are problems with the electronic board.
Common STANDART problems 07-18 and 24
Operation blinks slowly, Timer does not light, Defrost is off - split-system is in standby mode.
Operation is on, Timer is off, Defrost is off - normal operation split systems.
Operation blinks fast, Timer is off, Defrost blinks fast - the overload protection tripped 4 times in a row.
Operation is off, Timer flashes quickly, Defrost flashes quickly - the fan motor does not start for more than 1 minute.
Operation flashes quickly, Timer flashes quickly, Defrost flashes quickly - the compressor does not turn on or there are problems with the electronic board.
Operation is off, Timer is off, Defrost flashes quickly - problems with the tube sensor.
Operation is off, Timer flashes quickly, Defrost is off - problems with the air sensor.
Operation is on, Timer flashes quickly, Defrost is off - EEPROM error.
Common STANDART 24 violations
Operation flashes slowly, Timer is off, Defrost is off, Auto is off - split-system is in standby mode.
Operation is on, Timer is off, Defrost is off, Auto is off - normal operation of the split system.
Operation blinks quickly, Timer blinks quickly, Defrost blinks quickly, Auto blinks quickly - overload protection tripped 4 times in a row.
Operation off, Timer flashing quickly, Defrost off, Auto off - problems with the air sensor.
Operation flashes quickly, Timer is off, Defrost is off, Auto is off - problems with the tube sensor in the indoor unit.
Operation is off, Timer is off, Defrost flashes quickly, Auto is off - problems with the tube sensor of the external unit.
Operation is off, Timer is off, Defrost blinks quickly, Auto blinks quickly - protection of the external unit.
Operation is off, Timer is off, Defrost is off, Auto is blinking fast - (for systems with communication) communication failure between the external and internal units of the system.
Operation off, Timer off, Defrost off, Auto blinking fast - (for systems without communication) EEPROM error.
Breakdowns of STANDART 30-36 (indoor unit)
Operation blinks slowly, Timer is off, Defrost is off, Auto is off - split system is in standby mode.
Operation is on, Timer is off, Defrost is off, Auto is off - normal operation of the split system.
Operation blinks quickly, Timer blinks quickly, Defrost blinks quickly, Auto is turned off - overload protection tripped 4 times in a row.
Operation off, Timer flashing quickly, Defrost off, Auto off - problems with the air sensor.
Operation blinks quickly, Timer is off, Defrost is off, Auto is off - problems with the tube sensor in the indoor unit.
Operation off, Timer off, Defrost flashing quickly, Auto off - problems with the tube sensor of the external unit.
Operation blinks fast, Timer blinks quickly, Defrost is off, Auto is off - EEPROM error.
Operation is off, Timer is off, Defrost is blinking fast, Auto is blinking fast - a failure in the external unit of the system.
Operation is off, Timer is off, Defrost is off, Auto blinks quickly - communication failure between the external and internal units of the split system.
Malfunctions of the STANDART 30-36 (external unit)
On the General Climate STANDART 30-36 outdoor unit, fault signals are sent using a certain number of blinks of the light diode on the electronic board.
5 - lack of communication between the blocks.
4 - malfunctions with phases (skew, absence, improper alternation).
3 - increase in pressure in the system.
2 - problems with the tube sensor.
1 - a failure in the indoor unit.
Error codes of the FLAGMAN and CYBORG series
In the GC FLAGMAN and CYBORG split systems, in addition to the indicator lights, error messages are reported by alphanumeric characters on the display.
When decoding the error code of these General Climate models, one should not forget to pay attention to the display of the remote control.
Common failures FLAGMAN 07-18, CYBORG
E1, Operation blinks 1 time, Timer is off - EEPROM error.
E2, Operation blinks 2 times, Timer is off - there are problems with the electronic board of the indoor unit.
EU, Operation blinks 2 times, Timer is on - Freon leak, while the tube sensor does not show changes.
E3, Operation blinks 3 times, Timer is off - the fan motor in the indoor unit does not start for more than 1 minute.
E5, Operation blinks 5 times, Timer is off - problems with the air temperature sensor of the indoor unit.
E6, Operation blinks 6 times, Timer is off - problems with the tube sensor of the indoor unit.
Inherent flaws of FLAGMAN 24-28
Error codes of GC FLAGMAN 24-28 conditioners are similar to FLAGMAN 07-18 codes, but one more item is added to them.
E9, Operation blinks 9 times, Timer is off - communication failure between the external and internal units.
Common breakdowns of FLAGMAN 30-36
In models of split systems GC FLAGMAN 30-36, 2 more positions were added to the errors listed above.
E7, Operation blinks 7 times, Timer is off - problems with the tube sensor of the external unit
E8, Operation blinks 8 times, Timer is off - malfunctions with phases (skew, absence, incorrect rotation).
Error codes for ASTRA 07-36 models
In GC ASTRA 07-36 split systems, errors in operation are indicated by the appearance of alphanumeric codes on the display.
F0 - Freon leakage or high current supply to the compressor several times in a row.
F1 - problems with the air sensor in the indoor unit.
F2 - problems with the tube sensor in the indoor unit.
F3 - damage to the air sensor of the outdoor unit.
F4 - problems with the tube sensor of the outdoor unit.
F5 - malfunction of the sensor on the compressor discharge line.
C5 - lack of a blue jumper plug on the electronic board of the indoor unit.
H3 - overload protection tripped compressor.
H6 - the fan motor of the indoor unit does not start for more than 1 minute.
E1 - the high pressure sensor has tripped.
E2 - the frost sensor has triggered.
E3 - low pressure sensor has triggered.
E4 - protection against an increase in temperature along the discharge line.
E5 - high voltage supply to the compressor.
E6 - communication failure between the outdoor and indoor units.
E8 - compressor overload protection tripped.
U8 - problems with the control board.
Bug Fixes
Despite the different error codes in different models of General Climate air conditioners, in fact all the failures and breakdowns in them are the same.
Consider what to do to the owner of the equipment in the event of a particular error:
- Fan stop. If the fan fails to start for more than 1 minute, check the connection of the fan motor, as well as its serviceability. In the event of a component breakdown, it must be replaced. The air conditioning fan may also malfunction if there are problems with other components. For such diagnostics, it is recommended to invite an experienced wizard from a specialized service.
- Problems with temperature sensors. If the self-diagnosis system gives an error of a sensor, it is necessary to check the condition of the part, its integrity and the correct connection. For such a check, the owner of the air conditioner will need a multimeter. If the sensor fails, replace it.
- EEPROM crash. Sometimes you can get rid of the EEPROM error by simply restarting the air conditioner. To do this, turn off the power for a few minutes, then turn it on again. If the reboot did not help, the cause is problems with the electronic board. For such repairs, it is also recommended to invite a certified repairman.
- The compressor does not start. Compressor malfunctions usually begin after the filter is clogged with dust and dirt. The cause of the part failure can be overheating, damage to the winding or cable. The owner of the equipment can independently clean the filter of the device, but for more complex manipulations you will need an experienced locksmith.
- Repeated high voltage supply. With such an error, you should first disconnect the air conditioner from the power supply. The error will be automatically removed after regulating the power supply to the device.
- Communication failure between system units. Lack of communication leads to blocking the operation of the split system. The owner of the air conditioner can independently check the connection of the inter-unit cable and its integrity. If everything is in order with the cable, it means that the matter is in the electronic circuit boards of the blocks, and you need to contact the master.
It should be noted that malfunctions and malfunctions in the operation of air conditioners will occur much less frequently with regular routine inspection of household appliances.
Regular and timely cleaning of equipment and replacement of worn parts will ensure uninterrupted operation of air conditioners and split systems for a sufficiently long period.
To repair HVAC equipment, it’s advisable to contact a service center accredited by the manufacturer in order to restore the functionality of the GC air conditioners and carry out preventive maintenance, in which craftsmen with the appropriate approval work.
Conclusions and useful video on the topic
Timely disassembly and cleaning of the air conditioner will help to avoid errors in operation:
An example of a signal light indicator of the air conditioner when an error occurs:
This video demonstrates how to disassemble the General Climate air conditioning fan motor with your own hands:
If error messages appear, the owner of the General Climate air conditioner should not delay their removal. Self-repair of household appliances requires certain skills and the availability of specific tools. If the owner of the unit has both of them, he may well try to fix the breakdown on his own.
Otherwise, interference with the complex mechanism of an air conditioner or split system is fraught with more serious problems. An inexperienced owner of the equipment is recommended to invite an air conditioning repairman from an authorized service without trying to fix the device with your own hands.
Want to talk about how you yourself determined the cause of the malfunction of the air conditioner? Or is there a desire to share your own experience in performing simple repair work? Write comments, please, in the form below, post a photo on the topic of the article, ask questions.